Traffic signal cable is used for the interconnection of traffic signal equipment or other applications
requiring high core configurations with mechanical robustness.
Standard and Approval:
BS 6346, BS 6360, BS 7655
Cable Construction:
![]() |
|
- Conductor: Solid plain annealed copper, comply with BS 6360, Class 1 |
![]() |
Core Identification :
4 core - Red, Blue, Yellow, Green
Technical Characteristics:
- Rated voltage: 600/Kft volts
- Conductor Resistance: at 20°C: 18.1ohms/km(1.0mm2)
12.1 ohms/km(1.5mm2)
- Minimum bending radius: 6 x Ø
- Temperature range: -15º C - +70º C
- Short circuit temperature: 160ºC
- Flame retardant: BS EN 60332-1-2
Cable Parameter :
| Number of Cores | Nominal Conductor Area | Nominal Conductor Stranding | Insulation Thickness | Bedding Thickness | Nominal diameter of armour wire | Sheath Thickness | Nominal O/D | Approx Cable Weight |
| mm2 | NO./mm | mm | mm | mm | mm | mm | Kg/km | |
| Non armored cables | ||||||||
| 8 | 1.0 | 1/1.13 | 0.63 | - | - | 1.4 | 12.6 | 218 |
| 12 | 1.0 | 1/1.13 | 0.63 | - | - | 1.5 | 13.5 | 305 |
| 8* | 1.0 | 1/1.13 | 0.63 | - | - | 1.4 | 14.5 | 523 |
| Armored cables | ||||||||
| 4 | 1.0 | 1/1.13 | 0.63 | 0.8 | 0.9 | 1.4 | 13.3 | 325 |
| 8 | 1.0 | 1/1.13 | 0.63 | 0.8 | 0.9 | 1.4 | 15.6 | 413 |
| 12 | 1.0 | 1/1.13 | 0.63 | 0.8 | 1.25 | 1.5 | 17.9 | 567 |
| 16 | 1.0 | 1/1.13 | 0.63 | 0.8 | 1.25 | 1.5 | 19.9 | 774 |
| 20 | 1.0 | 1/1.13 | 0.63 | 0.8 | 1.25 | 1.6 | 22.0 | 905 |
| 4 | 1.5 | 1/1.38 | 0.63 | 0.8 | 0.9 | 1.4 | 12.5 | 363 |
| 8 | 1.5 | 1/1.38 | 0.63 | 0.8 | 0.9 | 1.4 | 15.8 | 534 |
| 12 | 1.5 | 1/1.38 | 0.63 | 0.8 | 1.25 | 1.5 | 18.5 | 704 |
| 16 | 1.5 | 1/1.38 | 0.63 | 0.8 | 1.25 | 1.6 | 20.0 | 836 |
| 20 | 1.5 | 1/1.38 | 0.63 | 0.8 | 1.25 | 1.6 | 21.5 | 1040 |
| 8* | 1.0 | 1/1.13 | 0.63 | 0.8 | 0.9 | 1.4 | 16.3 | 533 |